Go

SGF Phase- / Product Guard

level detector

Features
  • Product guard for watery and oily media
  • Welding sleeve system with modular process connections
  • Aseptic measuring point
  • Measuring signal output, frequenzy output
  • Wetting parts made of peek
  • Partly moulded
  • EHEDG certified, FDA conformal 
Technical specifications
  • High-grade steel connecting head Material No. 1.4305
  • Connection: M12 plug
  • Thread G 1/2” elastomerfree sealing system
  • probe tip made of PEEK (HPC-Tip No. 2)
  • Supply Voltage 12...32 VDC
  • Output Signal PNP, NPN Push-Pull or frequency output switchable
    Attention: There is no temperature compensation! Therefore, temperature fluctuations of the medium can lead to a change in the measuring signal.
  • Power up delay < 0,3s
  • Response time 0,2s
  • Ambient temperature-10...+70°C
  • Medium temperature durable 0...+100°C
  • Storage temperature -20...+70°C
  • Higher pressures on request
  • CIP-/SIP cleaning 0... + 150°C (30 min)
  • Working pressure 10 bar  
  • Protection class up to IP68 / 69K
  • Torque max. 20 Nm
  • Permissible Load: 100mA
Steffen Voss
Your contact person
Steffen Voss
Typical applications
  • Monitoring of different product phases
  • Differentiation of different product phases

Innovative Automation.
Temperature
Pressure
Filling levels
Analysis
Evaluation
Accessories