Type SKS 35 level detector

level detector

Features
  • weld-in sleeve system with modular process connections
  • optional aseptic measuring point
  • electrodes can be shortened independently
  • medium-affected components are made of stainless steel
  • material Nr. 1.4404 / HALAR® 3404DA-coating
  • FDA, EHEDG conform
Technical specifications
  • coated or uncoated electrodes (Coating for SIP applications (Sterilizing-In-Place) only conditionally suitable.)
  • optional stainless steel terminal head material Nr. 1.4305
  • optional with integrated level module
  • optional ports with terminal head:
    • screw connection
    • M12 plug-in
  • optional ports without terminal head:
    • M12 plug-in
    • fixed cable
  • thread G 1”, elastomer-free seal system
  • protection class IP69K
  • operating pressure max. 10 bar (higher pressure upon request)
  • tightening torque for seal system 10-20 Nm
  • CIP- / SIP cleaning 140ºC, 30 min
  • permissible substance temperature 0…100ºC
  • ambient temperature -10…60ºC
  • max. probe length 2 m
Frank Oehmann
Your contact person
Frank Oehmann
Typical applications
  • empty and full notification in containers
  • substance monitoring in pipelines for pump protection
  • container filling / drainage with level control

Innovative Automation.
Temperature
Pressure
Filling levels
Analysis
Evaluation