Features
- High accuracy
- Digital input for zero point adjustment
- Nominal pressure ranges up to 40 bar
- Relative Pressure
- Integrated control + indicator display optional
- Freely adjustable as tank level indicator & linearisation
up to 30 support points (via free software) - Configuration via display & possibility for
software- supported visualisation and configuration - Very quick compensation of temperature jump
- Wetting parts made of high-grade steel 1.4435
- Housing made of high-grade steel 1.4404
- Pressure screw for free positioning
- Individual measuring range adjustment
- Smallest measuring range 100 mbar
- Turndown 4:1
- Fourfold overload
- Galvanically isolated electronics
- Insulation voltage: 300V
- Totally front-flush membrane
- FDA, EHEDG-conformal
Technical specifications
- Accuracy according to IEC 60770: 0,1 % of adjusted measuring value
- Long-term stable
- Short-circuit-proof + reverse voltage protected
- Functional ranges (temperature):
Medium to be measured (permanent):-20 °C to 110 °C
Medium to be measured max. (1/2 h) up to 140 °C
High-Temperature-Version permanent up to 180 °C - Protection class up to IP 69 K (execution-dependently)
- Customized remarks:
-
- special measuring ranges
- variable electric and mechanical connections
- further designs upon request
Your contact person
Markus Wietkamp
Markus Wietkamp
- +49 5973 9474-41
- +49 5973 9474-74
- m.wietkamp@seli.de
Typical applications