Type TF 16 RTD thermomenter
RTD thermometer for aseptic applications (Brewing technology (Varivent))
Features
- process connection Varivent DN 50
- protective fitting with thermowell
- interchangeable terminal head
- interchangeable measuring insert (no process opening)
- optional with freely programmable head transmitter 4…20 mA
- optional: calibration certificate with tracing evidence according to DIN ISO 9000 ff (see data sheet calibration)
Technical specifications
- 1 or 2xPt100 class A
- Barstock diameter 8mm tapered down to 6mm made of raw material No. 1.4571 (V4A)
- installation length 35 mm
- thermowell length 70 mm
- aluminium / stainless steel terminal head with screw connection or M12-connector
- standard range of application -50ºC up to 400ºC (other ranges upon request)
- protection class (version dependent)
- operating pressure max. 25 bar